blob: 4bf89a8bc7001bcaa2b30265838098a2435823ce (
plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
|
/*! \page page_calibration Device Calibration
\tableofcontents
\section calibration_self Self-Calibration
UHD software comes with several self-calibration utilities for
minimizing IQ imbalance and DC offset. These utilities perform
calibration sweeps using transmit leakage into the receive path (special
equipment is not required). The results from a calibration are written
to a CSV file in the user's home directory. UHD software will
automatically apply corrections at runtime when the user re-tunes the
daughterboard LO. Calibration results are specific to an individual RF
board.
<b>Note:</b> When a calibration table is present, and the user wishes to
override the calibration settings through the API: the user should
re-apply the desired setting every time the LO is re-tuned.
UHD software comes with the following calibration utilities:
- **uhd_cal_rx_iq_balance:** - minimizes RX IQ imbalance vs. LO
frequency
- **uhd_cal_tx_dc_offset:** - minimizes TX DC offset vs. LO
frequency
- **uhd_cal_tx_iq_balance:** - minimizes TX IQ imbalance vs. LO
frequency
The following RF frontends are supported by the self-calibration
utilities:
- RFX Series transceiver boards
- WBX Series transceiver boards
- SBX Series transceiver boards
- CBX Series transceiver boards
- UBX Series transceiver boards
\subsection calibration_self_utils Calibration Utilities
UHD software installs the calibration utilities into
`<install-path>/bin`. **Disconnect** any external hardware from the
RF antenna ports, and run the following from the command line. Each
utility will take several minutes to complete:
uhd_cal_rx_iq_balance --verbose --args=<optional device args>
uhd_cal_tx_iq_balance --verbose --args=<optional device args>
uhd_cal_tx_dc_offset --verbose --args=<optional device args>
See the output given by `--help` for more advanced options, such as
manually choosing the frequency range and step size for the sweeps.
<b>Note:</b> Your daughterboard needs a serial number to run a calibration
utility. Some older daughterboards may not have a serial number. If this
is the case, run the following command to burn a serial number into the
daughterboard's EEPROM:
<install dir>/lib/uhd/utils/usrp_burn_db_eeprom --ser=<desired serial> --args=<optional device args>
\subsection calibration_data Calibration Data
By default, calibration files are stored in the user's home/application
directory:
- **Linux:** `${HOME}/.uhd/cal/`
- **Windows:** `%APPDATA%\.uhd\cal\`
If you would like to specify a custom directory, you can do so with the
`$UHD_CONFIG_DIR` environment variable:
- **Custom (any OS):** `${UHD_CONFIG_DIR}/.uhd/cal/`
Calibration files can easily be moved from one machine to another by copying the
"cal" directory. Re-running a calibration utility will replace the existing
calibration file. The old calibration file will be renamed so it may be
recovered by the user.
\subsection ignore_cal_file Ignoring Calibration Files
At runtime, the user can choose to ignore a daughterboard's calibration file by
adding "ignore-cal-file" to the arguments. With the UHD API, it can be done as
follows:
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~{.cpp}
uhd::device_addr_t hint;
hint["type"] = "usrp1";
hint["ignore-cal-file"] = "";
uhd::device_addrs_t dev_addrs = uhd::device::find(hint);
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Using tx_waveforms as an example, the user can apply this argument as follows:
tx_waveforms --args="addr=192.168.10.2,ignore-cal-file" --freq=100e6 --rate=1e6
*/
// vim:ft=doxygen:
|