aboutsummaryrefslogtreecommitdiffstats
path: root/host/lib/include/uhdlib/usrp
diff options
context:
space:
mode:
Diffstat (limited to 'host/lib/include/uhdlib/usrp')
-rw-r--r--host/lib/include/uhdlib/usrp/common/adf435x.hpp8
-rw-r--r--host/lib/include/uhdlib/usrp/common/adf535x.hpp25
2 files changed, 21 insertions, 12 deletions
diff --git a/host/lib/include/uhdlib/usrp/common/adf435x.hpp b/host/lib/include/uhdlib/usrp/common/adf435x.hpp
index 886c8d335..7989420dd 100644
--- a/host/lib/include/uhdlib/usrp/common/adf435x.hpp
+++ b/host/lib/include/uhdlib/usrp/common/adf435x.hpp
@@ -1,6 +1,7 @@
//
// Copyright 2015 Ettus Research LLC
// Copyright 2018 Ettus Research, a National Instruments Company
+// Copyright 2019 Ettus Research, A National Instruments Brand
//
// SPDX-License-Identifier: GPL-3.0-or-later
//
@@ -15,6 +16,7 @@
#include <uhd/types/ranges.hpp>
#include <uhd/utils/log.hpp>
#include <uhdlib/utils/math.hpp>
+#include <uhdlib/utils/narrow.hpp>
#include <functional>
#include <boost/math/special_functions/round.hpp>
#include <boost/thread.hpp>
@@ -112,7 +114,8 @@ public:
virtual void set_charge_pump_current(charge_pump_current_t cp_current) = 0;
- virtual double set_charge_pump_current(double current, bool flush = false) = 0;
+ virtual double set_charge_pump_current(
+ const double current, const bool flush = false) = 0;
virtual uhd::meta_range_t get_charge_pump_current_range() = 0;
@@ -321,7 +324,8 @@ public:
const auto cp_range = get_charge_pump_current_range();
const auto coerced_current = cp_range.clip(current, true);
- const int current_step = std::round((coerced_current / cp_range.step()) - 1);
+ const int current_step =
+ uhd::narrow_cast<int>(std::round((coerced_current / cp_range.step()) - 1));
UHD_ASSERT_THROW(current_step >= 0 and current_step < 16);
set_charge_pump_current(
diff --git a/host/lib/include/uhdlib/usrp/common/adf535x.hpp b/host/lib/include/uhdlib/usrp/common/adf535x.hpp
index c42f05b57..6af8556be 100644
--- a/host/lib/include/uhdlib/usrp/common/adf535x.hpp
+++ b/host/lib/include/uhdlib/usrp/common/adf535x.hpp
@@ -1,5 +1,6 @@
//
// Copyright 2015, 2017 Ettus Research, A National Instruments Company
+// Copyright 2019 Ettus Research, A National Instruments Brand
//
// SPDX-License-Identifier: GPL-3.0-or-later
//
@@ -13,6 +14,7 @@
#include <uhd/utils/log.hpp>
#include <uhd/utils/math.hpp>
#include <uhd/utils/safe_call.hpp>
+#include <uhdlib/utils/narrow.hpp>
#include <stdint.h>
#include <boost/format.hpp>
#include <functional>
@@ -54,22 +56,24 @@ public:
MUXOUT_DLD
};
- virtual void set_reference_freq(double fref, bool force = false) = 0;
+ virtual void set_reference_freq(const double fref, const bool force = false) = 0;
- virtual void set_pfd_freq(double pfd_freq) = 0;
+ virtual void set_pfd_freq(const double pfd_freq) = 0;
- virtual void set_feedback_select(feedback_sel_t fb_sel) = 0;
+ virtual void set_feedback_select(const feedback_sel_t fb_sel) = 0;
- virtual void set_output_power(output_power_t power) = 0;
+ virtual void set_output_power(const output_power_t power) = 0;
- virtual void set_output_enable(output_t output, bool enable) = 0;
+ virtual void set_output_enable(const output_t output, const bool enable) = 0;
- virtual void set_muxout_mode(muxout_t mode) = 0;
+ virtual void set_muxout_mode(const muxout_t mode) = 0;
- virtual double set_frequency(
- double target_freq, double freq_resolution, bool flush = false) = 0;
+ virtual double set_frequency(const double target_freq,
+ const double freq_resolution,
+ const bool flush = false) = 0;
- virtual double set_charge_pump_current(double target_current, bool flush = false) = 0;
+ virtual double set_charge_pump_current(
+ const double target_current, const bool flush = false) = 0;
virtual uhd::meta_range_t get_charge_pump_current_range() = 0;
@@ -238,7 +242,8 @@ public:
const auto cp_range = get_charge_pump_current_range();
const auto coerced_current = cp_range.clip(current, true);
- const int current_step = std::round((coerced_current / cp_range.step()) - 1);
+ const int current_step =
+ uhd::narrow_cast<int>(std::round((coerced_current / cp_range.step()) - 1));
UHD_ASSERT_THROW(current_step >= 0 and current_step < 16);
_regs.charge_pump_current =