diff options
author | Martin Braun <martin.braun@ettus.com> | 2014-03-23 15:11:26 +0100 |
---|---|---|
committer | Martin Braun <martin.braun@ettus.com> | 2014-04-09 17:25:09 +0200 |
commit | a74919c2a89a6b1ae40b526c4ceadf1108bfd186 (patch) | |
tree | 79cb43c5d7ed3caa1fe8b695001267f0cc8286bf /host/docs/calibration.dox | |
parent | 47bf17b50a305228cfd07ff6fbaff3ac4a30e811 (diff) | |
download | uhd-a74919c2a89a6b1ae40b526c4ceadf1108bfd186.tar.gz uhd-a74919c2a89a6b1ae40b526c4ceadf1108bfd186.tar.bz2 uhd-a74919c2a89a6b1ae40b526c4ceadf1108bfd186.zip |
docs: Moved manual to Doxygen
Diffstat (limited to 'host/docs/calibration.dox')
-rw-r--r-- | host/docs/calibration.dox | 70 |
1 files changed, 70 insertions, 0 deletions
diff --git a/host/docs/calibration.dox b/host/docs/calibration.dox new file mode 100644 index 000000000..494cfca49 --- /dev/null +++ b/host/docs/calibration.dox @@ -0,0 +1,70 @@ +/*! \page page_calibration Calibration Application Notes + +\tableofcontents + +\section calibration_self Self-Calibration + +UHD software comes with several self-calibration utilities for +minimizing IQ imbalance and DC offset. These utilities perform +calibration sweeps using transmit leakage into the receive path (special +equipment is not required). The results from a calibration are written +to a CSV file in the user's home directory. UHD software will +automatically apply corrections at runtime when the user re-tunes the +daughterboard LO. Calibration results are specific to an individual RF +board. + +<b>Note:</b> When a calibration table is present, and the user wishes to +override the calibration settings through the API: the user should +re-apply the desired setting every time the LO is re-tuned. + +UHD software comes with the following calibration utilities: + +- **uhd_cal_rx_iq_balance:** - mimimizes RX IQ imbalance vs. LO + frequency +- **uhd_cal_tx_dc_offset:** - mimimizes TX DC offset vs. LO + frequency +- **uhd_cal_tx_iq_balance:** - mimimizes TX IQ imbalance vs. LO + frequency + +The following RF frontends are supported by the self-calibration +utilities: + +- RFX Series transceiver boards +- WBX Series transceiver boards +- SBX Series transceiver boards +- CBX Series transceiver boards + +\subsection calibration_self_utils Calibration Utilities + +UHD software installs the calibration utilities into +`<install-path>/bin`. **Disconnect** any external hardware from the +RF antenna ports, and run the following from the command line. Each +utility will take several minutes to complete. : + + uhd_cal_rx_iq_balance --verbose --args=<optional device args> + uhd_cal_tx_iq_balance --verbose --args=<optional device args> + uhd_cal_tx_dc_offset --verbose --args=<optional device args> + +See the output given by --help for more advanced options, such as: +manually choosing the frequency range and step size for the sweeps. + +<b>Note:</b> Your daughterboard needs a serial number to run a calibration +utility. Some older daughterboards may not have a serial number. If this +is the case, run the following command to burn a serial number into the +daughterboard's EEPROM: : + + <install dir>/lib/uhd/utils/usrp_burn_db_eeprom --ser=<desired serial> --args=<optional device args> + +\subsection calibration_ Calibration Data + +Calibration files are stored in the user's home/application directory. +They can easily be moved from machine to another by copying the "cal" +directory. Re-running a calibration utility will replace the existing +calibration file. The old calibration file will be renamed so it may be +recovered by the user. + +- **Linux:** `${HOME}/.uhd/cal/` +- **Windows:** `%APPDATA%\.uhd\cal\` + +*/ +// vim:ft=doxygen: |