uhd: some more notes on calibration utils
-rw-r--r--host/docs/calibration.rst7
1 files changed, 6 insertions, 1 deletions
diff --git a/host/docs/calibration.rst b/host/docs/calibration.rst
index 0aaace8f4..14e66a312 100644
--- a/host/docs/calibration.rst
+++ b/host/docs/calibration.rst
@@ -11,9 +11,14 @@ The UHD comes with several self-calibration utilities for minimizing IQ imbalanc
These utilities perform calibration sweeps using transmit leakage into the receive path
(special equipment is not required).
The results from a calibration are written to a csv file in the user's home directory.
-UHD will automatically apply corrections at runtime when the user changes settings.
+UHD will automatically apply corrections at runtime when the user re-tunes the daughterboard LO.
Calibration results are specific to an individual RF board.
+**Note:**
+When a calibration table is present,
+and the user wishes to override the calibration settings through the API:
+the user should re-apply the desired setting every time the LO is re-tuned.
+
UHD comes with the following calibration utilities:
* **uhd_cal_rx_iq_balance:** - mimimizes RX IQ imbalance vs LO frequency