1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
|
/*! \page page_sync Device Synchronization
\tableofcontents
The following application notes explain how to synchronize multiple USRP
devices with the goal of transmitting or receiving time-aligned samples
for MIMO or other applications requiring multiple USRP devices operating
synchronously.
<b>Note:</b> The following synchronization notes do not apply to USRP1,
which does not support the advanced features available in newer
products.
\section sync_commonref Common Reference Signals
USRP devices take two reference signals in order to synchronize clocks
and time:
- A 10 MHz reference to provide a single frequency reference for all
devices.
- A pulse-per-second (PPS) to synchronize the sample time across
devices.
The way these reference signals are provided to the devices varies.
\subsection sync_commonref_pps External PPS and 10 MHz reference signals
Most USRPs have SMA connnectors on the front- or back-panel to provide these
signals (10 MHz reference and PPS). These signals could be provided by an
\ref page_octoclock, an external/third-party GPSDO, a measurement device's
reference outputs, or some other clock-generating device.
Connect these SMA connectors to the reference sources. In your software, select
the external reference inputs as clock and time sources:
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~{.cpp}
usrp->set_clock_source("external");
usrp->set_time_source("external");
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
<b>Note:</b> For users generating their own signals for the external SMA
connectors, the PPS should be clocked from the 10 MHz reference. See the
application notes for your device for specific signal requirements (e.g.,
voltage).
<b>Note (N200/N210 and B100 only):</b> Sometimes the delay on the PPS signal will
cause it to arrive inside the timing margin of the FPGA sampling clock, causing
PPS edges to be separated by less or more than 100 million cycles of the FPGA
clock.
If this is the case, you can change the edge reference of the PPS signal
with this parameter:
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~{.cpp}
usrp->set_time_source("_external_");
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
\subsection sync_commonref_mimo MIMO cable reference signals (N200-Series, USRP2)
Use the MIMO expansion cable to share reference sources (USRP2 and
N200-Series only). The MIMO cable can be used to synchronize one device to
another device. Users of the MIMO cable may use Method 1 (explained below) to
synchronize multiple pairs of devices.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~{.cpp}
usrp->set_clock_source("mimo");
usrp->set_time_source("mimo");
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
\section sync_time Synchronizing the Device Time
The purpose of the PPS signal is to synchronously latch a time into the
device. You can use the uhd::usrp::multi_usrp::set_time_next_pps() function to either
initialize the sample time to 0 or an absolute time, such as GPS time or
UTC time. For the purposes of synchronizing devices, it doesn't matter
what time you initialize to when using uhd::usrp::multi_usrp::set_time_next_pps().
\subsection sync_time_reg Method 1 - poll the USRP time registers
One way to initialize the PPS edge is to poll the "last PPS" time from
the USRP device. When the last PPS time increments, the user can
determine that a PPS has occurred:
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~{.cpp}
const uhd::time_spec_t last_pps_time = usrp->get_time_last_pps();
while (last_pps_time == usrp->get_time_last_pps()){
//sleep 100 milliseconds (give or take)
}
// This command will be processed fairly soon after the last PPS edge:
usrp->set_time_next_pps(uhd::time_spec_t(0.0));
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
\subsection sync_time_gpsdo Method 2 - query the GPSDO for seconds
Most GPSDOs can be configured to output a NMEA string over the serial
port once every PPS. The user can wait for this string to determine the
PPS edge, and the user can also parse this string to determine GPS time:
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~{.cpp}
//call user's function to wait for NMEA message...
usrp->set_time_next_pps(uhd::time_spec_t(0.0));
-- OR --
//call user's function to wait for NMEA message...
//call user's function to parse the NMEA message...
gps_time = VALUE_IN_NMEA_MESSAGE;
// At the next PPS edge, set the device time to the GPS time:
usrp->set_time_next_pps(uhd::time_spec_t(gps_time+1));
// Now the device time should be in sync with the GPS time.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Take a look at the `sync_to_gps` example for more detail.
\subsection sync_time_mimocable Method 3 - MIMO cable
Note: This only applies to USRP2 and N200/N210. This method does *not*
require a separate PPS input to the devices, but it is limited to
a total of 2 USRPs.
A USRP2 device can synchronize its time to another USRP device via the
MIMO cable. Unlike the other methods, this does not use a real "pulse
per second". Rather, the USRP device sends an encoded time message over
the MIMO cable. The slave device will automatically synchronize to the
time on the master device. See \ref usrp2_mimocable for more detail.
\section sync_phase Synchronizing Channel Phase
\subsection sync_phase_cordics Align CORDICs in the DSP
In order to achieve phase alignment between USRP devices, the CORDICS in
both devices must be aligned with respect to each other. This is easily
achieved by issuing stream commands with a time spec property, which
instructs the streaming to begin at a specified time. Since the devices
are already synchronized via the 10 MHz and PPS inputs, the streaming
will start at exactly the same time on both devices. The CORDICs are
reset at each start-of-burst command, so users should ensure that every
start-of-burst also has a time spec set.
For receive, a burst is started when the user issues a stream command.
This stream command should have a time spec set:
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~{.cpp}
uhd::stream_cmd_t stream_cmd(uhd::stream_cmd_t::STREAM_MODE_NUM_SAMPS_AND_DONE);
stream_cmd.num_samps = samps_to_recv;
stream_cmd.stream_now = false;
stream_cmd.time_spec = time_to_recv;
usrp->issue_stream_cmd(stream_cmd);
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
For transmit, a burst is started when the user calls send(). The
metadata should have a time spec set: :
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~{.cpp}
uhd::tx_metadata_t md;
md.start_of_burst = true;
md.end_of_burst = false;
md.has_time_spec = true;
md.time_spec = time_to_send;
//send a single packet
size_t num_tx_samps = tx_streamer->send(buffs, samps_to_send, md);
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
\subsection sync_phase_lo Align LOs in the front-end (SBX, UBX)
Using timed commands, multiple frontends can be tuned at a specific
time. This timed-tuning ensures that the phase offsets between VCO/PLL
chains will remain constant after each re-tune. See notes below:
- Phase synchronization with the UBX is only supported on the X3x0 Series
- Phase synchronization with the SBX works on both N2x0 and X3x0 Series
- There is a random phase offset between any two frontends
- This phase offset is different for different LO frequencies
- This phase offset remains constant after retuning
- This phase offset will drift over time due to thermal and other characteristics
- Periodic calibration will be necessary for phase-coherent applications
Code snippet example, tuning with timed commands:
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~{.cpp}
//we will tune the frontends in 100ms from now
uhd::time_spec_t cmd_time = usrp->get_time_now() + uhd::time_spec_t(0.1);
//sets command time on all devices
//the next commands are all timed
usrp->set_command_time(cmd_time);
//tune channel 0 and channel 1
usrp->set_rx_freq(1.03e9, 0); // Channel 0
usrp->set_rx_freq(1.03e9, 1); // Channel 1
//end timed commands
usrp->clear_command_time();
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
\subsection sync_phase_lootherfe Align LOs in the front-end (others)
After tuning the RF front-ends, each local oscillator may have a random
phase offset due to the dividers in the VCO/PLL chains. This offset will
remain constant after the device has been initialized, and will remain
constant until the device is closed or re-tuned. This phase offset is
typically removed by the user in MIMO applications, using a training
sequence to estimate the offset. It will be necessary to re-align the
LOs after each tune command.
*/
// vim:ft=doxygen:
|