/*! \page page_properties RFNoC Block Properties \tableofcontents \section props_intro Introduction One of the mechanisms that RFNoC blocks can use to control their configuration are *properties*. There are two types of properties within a block: User properties, and edge properties. To illustrate these types of properties, we start with an example: Take DDC block (uhd::rfnoc::ddc_block_control), which can take in a signal of a certain sampling rate, shift it in frequency, and resample to a lower sampling rate. First, we take a look at the *user properties*. User properties are properties which are attributes of a block, they simply define certain characteristics of the block. Here, we focus on two user properties: The frequency and the decimation. The former is a floating point value which stores, in Hz, the amount by which the incoming signal is shifted in frequency. The decimation is the integer value by which the incoming sampling rate is divided. Put differently, the user properties control the behaviour of the DDC block. On top of that, the DDC block also has an edge property for the sampling rate on both the outgoing edge and the incoming edge. This property describes something about the data on this graph edge. ``` ┌──────────────┐ │ DDC Block │ samp_rate │ │ samp_rate ───────────> - freq ├─────────> │ - decim │ │ │ └──────────────┘ ``` The key thing, which separates properties from other attributes associated with the block, is that we can describe relationships between the properties. In this example, the following relationships exist: - The `samp_rate` property on the outgoing edge equals the `samp_rate` property on the incoming edge divided by the `decim` value. - The normalized frequency (required to program the digital hardware) is calculated by dividing the `freq` user property by the `samp_rate` edge property on the incoming edge. User properties also act as an API for RFNoC blocks. It is possible to access user properties using the uhd::rfnoc::node_t::get_property() and uhd::rfnoc::node_t::set_property() and uhd::rfnoc::node_t::set_properties() APIs. A list of user properties can be read by calling uhd::rfnoc::node_t::get_property_ids(). Often, block controllers will provide explicit C++ APIs on top of the user properties. For example, the DDC block control has an API call uhd::rfnoc::ddc_block_control::set_freq(), which provides additional features on top of the user property (e.g., it can also set a command time). Direct access of user properties is thus often not necessary, and can be considered a lower-level API than directly calling block APIs. \section props_propprop Property Propagation By itself, these relationships between properties are already useful to describe something about the block, but the real power comes when connecting blocks. This allows blocks to communicate their settings, even without knowing which block they're connected to. Consider the following example, using a radio block (uhd::rfnoc::radio_control), the DDC block, and a hypothetical Modem Block, which expects incoming samples at a fixed data rate of 20 Msps. Assume we are running this flow graph in a USRP X310, with a master clock rate of 200 Msps: ``` ┌─────────────┐ ┌──────────────┐ ┌──────────────┐ │ Radio Block │ │ DDC Block │ │ Modem Block │ │ │samp_rate │ │ samp_rate│ │ │ ├──────────> - freq ├──────────> │ │ │ │ - decim │ │ │ │ │ │ │ │ │ └─────────────┘ └──────────────┘ └──────────────┘ ``` Upon initialization, the radio block will configure its hardware clocks, and set a sampling rate of 200 Msps on its outgoing edge property (`samp_rate`). This property is also the incoming edge property of the DDC block, which means it is now initialized its sampling rate to 200 Msps. Setting the `freq` property will now work accurately, because it can calculate normalized frequencies. The Modem Block will set its incoming edge property `samp_rate` to 20 Msps, which is also the outgoing edge property of the DDC block. The DDC block must now find a way to reconcile these edge properties, which it can achieve by setting the `decim` user property to 20. Now, the DDC has automatically set a decimation without anyone calling into its rate-changing APIs, and without the Modem Block or the Radio Block knowing anything about how the DDC block works. Similarly, if the Modem Block would have requested a sampling rate of 30.72 Msps, the DDC would not have been able to resolve the incoming and outgoing sampling rates with an integer decimation factor. It would have requested the radio to produce an integer multiple of 30.72 Msps, which the radio can't provide. Using properties, UHD would be able to throw an exception, telling the user that the requested combination is not achievable. \section props_multichan Properties on multi-channel blocks and resource types The DDC block is configurable to have a variable number of channels, and the same is true for the properties. To accommodate for this, both edge and user properties have an index value. A multi-channel DDC block is more accurately depicted as such with regard to its properties: ``` ┌──────────────┐ │ DDC Block │ samp_rate[i] │ │ samp_rate[i] ──────────── > - freq[i] ├──────────────> │ - decim[i] │ │ │ └──────────────┘ ``` \b Note: The index of edge properties is tightly coupled to the actual edge being used (i.e., `samp_rate` on input edge 0 also has a property index of 0). However, user properties do not enforce this relationship. In the DDC block, it would be possible for the user property `decim[0]` to control channel 1 (which it doesn't). This is useful for properties that don't map directly to channels (e.g., a simpler version of the DDC block might only have a single `decim` user property for all channels). In summary, to accurately identify a property, not only its name is required, but also its type (input edge, user property, or output edge) and its index. For the sake of convenience, the type and index are sometimes combined into a uhd::rfnoc::res_source_info object. \section props_define Defining Properties To define properties in an RFNoC block, the block controller needs to declare class attributes of type uhd::rfnoc::property_t. This is a template type which can take in different types of C++ types (e.g., the `decim` user property is an integer type, and the `freq` user property is of type `double`). Upon creation of the class attribute, properties are configured with their property name (e.g. `freq`, `decim`), optionally a default value, their type (user or edge property), and their index. The uhd::rfnoc::ddc_block_control defines its frequency property attribute variable as such: ~~~{.cpp} class ddc_block_control_impl : public ddc_block_control { // ...all the other declarations ... private: // Declare the property_t attributes for the frequency std::vector> _freq; }; ~~~ Next, the attribute needs to be initialized, like any other class attribute. If we were to hard-code a 2-channel DDC with a default frequency shift of 0 Hz, this would be a valid initialization: ~~~{.cpp} // ... other initializations ... _freq.reserve(2); _freq.push_back(property_t("freq", 0.0, {res_source_info::USER, 0})); _freq.push_back(property_t("freq", 0.0, {res_source_info::USER, 1})); ~~~ \b Note: It is important to choose a container for properties which does not modify their memory locations! If a `std::vector<>` is chosen as a container, it is required to `reserve()` memory before filling the container. Up until now, the property is just a class attribute. For UHD to make it available for property propagation, it needs to be registered by calling uhd::rfnoc::node_t::register_property(): ~~~{.cpp} // ... this is still happening within the context of the block controller: register_property(&_freq[0]); register_property(&_freq[1]); ~~~ The final step of creating properties is to define the relationship between them, which is covered in the following section. \section props_resolvers Property Resolvers and Property Resolution A property resolver is a function object that is associated with an input list of properties and an output list of properties. The function object will be executed when any property on the input list changes. It may modify any property in the output list. For more details, see uhd::rfnoc::node_t::add_property_resolver(). As an example, here is a shortened version of one of the resolvers in uhd::rfnoc::ddc_block_control: ~~~{.cpp} add_property_resolver( {&decim}, // Input list: We trigger this when the user changes `decim` {&decim, &samp_rate_out, &samp_rate_in}, // Output list: These will be changed // The resolver function is passed in as a lambda: [this, chan, ...]() { // The capture list was cropped for better readability RFNOC_LOG_TRACE("Calling resolver for `decim'@" << chan); decim = coerce_decim(double(decim.get())); // Only some decimations are valid if (decim.is_dirty()) { // If nothing changes, don't poke any registers set_decim(decim.get(), chan); // This will control hardware registers } if (samp_rate_in.is_valid()) { samp_rate_out = samp_rate_in.get() / decim.get(); } else if (samp_rate_out.is_valid()) { samp_rate_in = samp_rate_out.get() * decim.get(); } }); ~~~ A few noteworthy comments: - Even though this function object is called when modifying `decim`, it is still possible to coerce `decim` to a different, valid value. - Properties may be in an invalid state (e.g., if they were never initialized) which needs to be checked before accessing such properties. See also uhd::rfnoc::property_base_t::is_valid(). - Properties can be modified by assigning values to them which match their template type. - We can tell if a property was modified by checking its clean/dirty state (see also uhd::rfnoc::property_base_t::is_dirty()). - When the resolver function completes, we have ensured that `samp_rate_in`, `samp_rate_out`, and `decim` are in a consistent state. \subsection props_resolvers_cldrty Clean/Dirty Attributes of Properties To keep track of which properties have been modified, every property has a "dirty" flag that is set when a property's value is changed. This dirty flagged is also used to determine which property resolver functions need to be called. A property resolver may modify (and thus dirty) other properties, but resolvers may never set properties to conflicting values. For example, the DDC block controller has a different resolver that is called when its input sampling rate is modified, but it uses the same equations to relate decimation, input rate, and output rate so the resulting values are consistent. Imagine a block that has both an `fft_size` and `bin_width` user property. They are related by `bin_width = sampling_rate_in / fft_size`, where `sampling_rate_in` is an input edge property. Adding two separate resolvers like this is valid: ~~~{.cpp} add_property_resolver( {&fft_size}, {&bin_width}, [this, &fft_size, &bin_width, &samp_rate_in]() { // This will trigger the other resolver bin_width = samp_rate_in.get() / fft_size.get(); }); add_property_resolver( {&bin_width}, {&fft_size}, [this, &fft_size, &bin_width, &samp_rate_in]() { // This will trigger the other resolver fft_size = samp_rate_in.get() / bin_width.get(); }); ~~~ Both resolvers will modify the input for the other resolver. However, because they use the same equations, this does not incur a circular resolution. \b Note: When using floating-point type properties, it is possible to incur a circular resolution when floating point rounding errors occur, so they need to be accounted for. See, for example, the implementation of uhd::rfnoc::ddc_block_control. When all resolvers with dirty inputs have been run, and no conflicts have occurred, properties are flagged clean. When this happens, a clean callback is executed which can trigger further actions (it may not, however, modify properties. See uhd::rfnoc::node_t::register_property()). As an example, assume a block configures an FFT size. It first checks the FFT size is as power of two, then writes the log2 of the FFT size to a hardware register. The following two implementations have the same effect. First, we use the resolver to write to the hardware: ~~~{.cpp} register_property(&fft_size); add_property_resolver( {&fft_size}, {&fft_size}, [this, &fft_size]() { fft_size = coerce_to_power_of_2(fft_size.get()); if (fft_size.is_dirty()) { this->regs().poke32(FFT_SIZE_REG, log2(fft_size.get())); } }); ~~~ Alternatively, we poke the register as part of cleaning the property: ~~~{.cpp} register_property( &fft_size, [this, &fft_size](){ this->regs().poke32(FFT_SIZE_REG, log2(FFT_SIZE.get()); } ); add_property_resolver( {&fft_size}, {&fft_size}, [this, &fft_size]() { fft_size = coerce_to_power_of_2(fft_size.get()); }); ~~~ The differences are subtle: - The second approach separates the hardware interaction from the coercion/resolution logic. Here, the resolver is *only* responsible for maintaining the property in a valid state. - In the first approach, the register is poked as soon as the new value is known. In the second approach, the poke happens only after the resolution is complete. In this particular instance, the second approach is the more readable and is recommended. However, not always do properties map to poking registers (or other actions) in a clean, one-to-one manner, which is when the first approach is better suited. \section props_graph_resolution Graph Property Resolution In an RFNoC graph, after calling `uhd::rfnoc::rfnoc_graph::commit()`, edge properties are used to resolve properties of a whole graph. When any property is changed, the corresponding block's properties are resolved as explained before. However, by modifying the edge properties of a block, other blocks' properties may be dirtied as well. In this case, the resolver algorithm will keep resolving blocks until either all properties are clean, or a conflict is detected. \subsection props_graph_resolution_back_edges Back edges The graph object uses a topological sort to identify the order in which blocks are resolved. However, in RFNoC, it is OK to have loops, or *back edges*. Consider the following graph: ``` ┌─────────────┐ ┌──────────────┐ ┌──────────────┐ │ │ │ │ │ │ │ Radio Block ├──────────> DDC Block ├──────────> Custom DSP │ │ │ │ │ │ │ └─────^───────┘ └──────────────┘ └──────┬───────┘ │ │ │ back edge │ └───────────────────────────────────────────────────┘ ``` In this application, we receive a signal, use the DDC block to correct a frequency offset digitally, and then apply some custom DSP before transmitting the signal again, using the same radio block. In order to create a valid graph that UHD can handle, one of the edges needs to be declared a back edge. Edge properties are not propagated across back edges, however, they must still match up after property resolution is done. For example, if the DDC were to be configured to decimate the sampling rate, and the custom DSP block would not correct for that, the output edge property `samp_rate` of the custom DSP block would be mismatched compared to the input edge property `samp_rate` of the radio. \section props_unknown Handling unknown properties Since every block can define its own edge- and user properties, it is likely that a block may not have defined an edge property that an up- or downstream block has. Consider the example of the previous section. The "Custom DSP" block may not have defined edge properties for the sampling rate. The Radio and DDC blocks however, do have a `samp_rate` edge property defined. The way blocks handle such properties is by setting a *forwarding policy* (see uhd::rfnoc::node_t::set_prop_forwarding_policy() and uhd::rfnoc::node_t::set_prop_forwarding_map()). There are several forwarding policies (see uhd::rfnoc::node_t::forwarding_policy_t). The most common forwarding policy is uhd::rfnoc::node_t::forwarding_policy_t::ONE_TO_ONE. Here, properties that are applied to an input edge are forwarded to the corresponding output edge. For more special use cases, uhd::rfnoc::node_t::forwarding_policy_t::USE_MAP can be used to define forwarding rules for non-static cases (e.g., see uhd::rfnoc::switchboard_block_control). \section props_common_props Common Properties There are some properties that are commonly used, and blocks should use these property names if appropriate: Edge Properties: - `type`: It is recommended to always use this property on an edge. It should describe the data type on this edge so the graph can see if types match. The type descriptions are the same as with CPU and OTW types (e.g., sc16, fc32, sc8, u8, ...). - `samp_rate`: Whenever a "sampling rate" is applicable, edges should set this property. DDC, DUC, and Radio blocks all use this for configuring rates and verifying sample rates match. - `scaling`: This property describes how a block has distorted a signal with respect to amplitude. A scaling value of 0.99 means that a signal that used to be fullscale (max. amplitude of 1.0) will only have a maximum amplitude of 0.99. For example, the DDC and DUC blocks use this property to signal how much they have affected the amplitude. The TX and RX streamer objects can then apply the inverse of this scaling factor to correct for the scaling before returning the signal to the user. User properties: - `spp`: Blocks that produce data in chunks of samples can use this to describe their "sample per packet" values. Example: uhd::rfnoc::radio_control - `interp`, `decim`: Interpolation and decimation factors when doing rational resampling. Examples: uhd::rfnoc::ddc_block_control, uhd::rfnoc::duc_block_control See also the following sections for properties that receive special treatment by the framework. \section props_special_props Special Properties There is a small number of edge properties that treated differently by the RFNoC framework. \section props_special_props_tickrate Tick Rate The "tick rate" is the rate that is used for converting floating point timestamps into integer ticks. The tick rate has the additional constraint that within a graph, the tick rate must be the same for all blocks. Therefore, the tick rate is defined by the framework for all blocks that derive from uhd::rfnoc::noc_block_base, and block authors cannot register properties with that name. The tick rate property is propagated to all edges to enforce all blocks having the same tick rate. Some blocks (like the radio blocks) set the tick rate via their direct access to the hardware, but most blocks use the property propagation mechanism to distribute the tick rate. To read back the tick rate, use uhd::rfnoc::noc_block_base::get_tick_rate(). Within a block implementation, the uhd::rfnoc::noc_block_base::set_tick_rate() API call can be used to update the tick rate (most blocks do not have to do this). \section props_special_props_mtu MTU Because the MTU is part of the RFNoC framework (it is constrained by the buffer size chosen between blocks, and is thus read back from a register in the FPGA), its property is also created by the RFNoC framework for all blocks, and block authors cannot use the name `mtu` for their properties. However, MTUs can differ within a graph, and blocks might have additional constraints on MTU. For this reason, accessing the MTU properties directly is not possible from within a block controller, but rfnoc::noc_block_base provides several APIs to interact with MTUs: - noc_block_base::get_mtu(): Reading back the MTU determined by property propagation on a particular edge. - noc_block_base::set_mtu(): Reduce the MTU on a particular edge. *Increasing* the MTU is not possible. - noc_block_base::set_mtu_forwarding_policy(): Set the MTU forwarding policy. - noc_block_base::get_mtu_prop_ref(): Request access to a MTU property reference, which can be used to trigger property propagation off of an MTU change. Many blocks (e.g., uhd::rfnoc::ddc_block_control, uhd::rfnoc::duc_block_control) do not resize blocks as they pass through them. That means the input MTU of these blocks equals the output MTU. Thus, they set the MTU forwarding policy to uhd::rfnoc::node_t::forwarding_policy_t::ONE_TO_ONE. */ // vim:ft=doxygen: