| Commit message (Collapse) | Author | Age | Files | Lines |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
When executing eeprom-init on E320 (which was originally written for
N310), it would use defaults from N310, potentially causing issues.
These issues would have arisen if we letter-revved the E320 one more
time (because at rev 5, N310 had a compatibility cutover).
Summary of changes:
- eeprom-init will now read values *not* given on the command line from
the existing content of the EEPROM, if it contains valid data. This
means that DT, MCU, and rev compat values will no longer get
auto-derived if the EEPROM already contained "good" values.
- If the EEPROM is empty or corrupted, eeprom-init will no longer run if
the pid value is not provided. This is to avoid N310 defaults being
written to E320 EEPROMs.
- A README is added to explain which devices use which utilities.
- PID checks are more strict now. It is unlikely we'll build new devices
using the old EEPROM format (prior to TLV), so we can check
specifically for E320, N3x0.
- The hard-coded list of PIDs for the EEPROM tools are moved to
a central location (eeprom-pids.h).
- The code to derive values for DT/MCU/rev compat from the rev is now
pid-specific and no longer device-agnostic.
|
|
|
|
|
|
|
|
|
|
| |
This includes a rev_compat field, which we can use to identify the last
hardware revision this hardware is compatible with. Example: Say the
current hardware revision is 7, but it is compatible with version 5,
then we store 7 as the current rev, and 5 as the rev_compat. Software
can now check the rev_compat rather than the current rev for
compatibility. This makes MPM more future-proof against minor,
compatible hardware changes.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Introduce dt-compat and mcu-compat fields into the eeprom
structure.
For the motherboard eeprom this is straightforward, since
there's still padding bytes that could be (ab)used for this.
On the dboard side more creativity is required and the
original revision field of 2 bytes is reduced to only
one byte revision and one byte dt-compat.
Since this will only affect new units being backwards
compatible with older versions of the bootloader is not
an issue.
Reviewed-by: Brent Stapleton <brent.stapleton@ettus.com>
Signed-off-by: Moritz Fischer <moritz.fischer@ettus.com>
|
|
|
|
|
| |
- Fix typo in company name (missing 'a')
- Updated SPDX license identifier to version 3.0
|
|
Actually-written-by: Moritz Fischer <moritz.fischer@ettus.com>
|