diff --git a/host/docs/calibration.rst b/host/docs/calibration.rst
index 8ba3477b8..23bef01b7 100644
--- a/host/docs/calibration.rst
+++ b/host/docs/calibration.rst
@@ -5,14 +5,15 @@ UHD - Calibration Application Notes
.. contents:: Table of Contents
------------------------------------------------------------------------
-Self-calibration
+Self-Calibration
------------------------------------------------------------------------
-UHD software comes with several self-calibration utilities for minimizing IQ imbalance and DC offset.
-These utilities perform calibration sweeps using transmit leakage into the receive path
-(special equipment is not required).
-The results from a calibration are written to a CSV file in the user's home directory.
-UHD software will automatically apply corrections at runtime when the user re-tunes the daughterboard LO.
-Calibration results are specific to an individual RF board.
+UHD software comes with several self-calibration utilities for minimizing IQ
+imbalance and DC offset. These utilities perform calibration sweeps using
+transmit leakage into the receive path (special equipment is not required).
+The results from a calibration are written to a CSV file in the user's home
+directory. UHD software will automatically apply corrections at runtime when
+the user re-tunes the daughterboard LO. Calibration results are specific to an
+individual RF board.
**Note:**
When a calibration table is present,
@@ -27,10 +28,10 @@ UHD software comes with the following calibration utilities:
The following RF frontends are supported by the self-calibration utilities:
- * RFX transceiver board
- * WBX transceiver board
- * SBX transceiver board
- * CBX transceiver board
+ * RFX Series transceiver boards
+ * WBX Series transceiver boards
+ * SBX Series transceiver boards
+ * CBX Series transceiver boards
********************************************
Calibration Utilities
@@ -54,7 +55,7 @@ may not have a serial number. If this is the case, run the following command to
into the daughterboard's EEPROM:
::
- <install dir>/share/uhd/utils/usrp_burn_db_eeprom --ser=<desired serial> --args=<optional device args>
+ <install dir>/lib/uhd/utils/usrp_burn_db_eeprom --ser=<desired serial> --args=<optional device args>
********************************************
Calibration Data