aboutsummaryrefslogtreecommitdiffstats
path: root/host
diff options
context:
space:
mode:
authorMarcus Müller <marcus@hostalia.de>2015-04-14 12:46:11 +0200
committerMartin Braun <martin.braun@ettus.com>2015-04-14 13:33:12 -0500
commitc0d7b8f0cfc23162e41712cb8c5ee2a1d5d8d4bd (patch)
treecbcdbd8c4c237db361b6f7fc7aadfb8072a97891 /host
parent61e806b8fc2243d619b0498b6e9da9c3e3ba7aa7 (diff)
downloaduhd-c0d7b8f0cfc23162e41712cb8c5ee2a1d5d8d4bd.tar.gz
uhd-c0d7b8f0cfc23162e41712cb8c5ee2a1d5d8d4bd.tar.bz2
uhd-c0d7b8f0cfc23162e41712cb8c5ee2a1d5d8d4bd.zip
docs: Updated daughterboard information
- Removed CBX from list of phase-sync'able dboards, added UBX - Added information about UBX phase ambiguity on N2x0
Diffstat (limited to 'host')
-rw-r--r--host/docs/sync.dox6
1 files changed, 4 insertions, 2 deletions
diff --git a/host/docs/sync.dox b/host/docs/sync.dox
index 8c16eb046..aaae88702 100644
--- a/host/docs/sync.dox
+++ b/host/docs/sync.dox
@@ -152,7 +152,7 @@ metadata should have a time spec set: :
size_t num_tx_samps = tx_streamer->send(buffs, samps_to_send, md);
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
-\subsection sync_phase_lo Align LOs in the front-end (SBX, WBX, CBX)
+\subsection sync_phase_lo Align LOs in the front-end (SBX, WBX, UBX)
Using timed commands, multiple frontends can be tuned at a specific
time. This timed-tuning ensures that the phase offsets between VCO/PLL
@@ -161,7 +161,9 @@ chains will remain constant after each re-tune. See notes below:
- There is a random phase offset between any two frontends
- This phase offset is different for different LO frequencies
- This phase offset remains constant after retuning
- - Due to a divider, WBX phase offset will be randomly +/- 180 deg after re-tune
+ - Due to a divider, WBX phase offset will be randomly +/- 180 deg after re-tune on all USRPs.
+ - Due to a divider, UBX phase offset will be randomly +/- 180 deg after re-tune on N200/N210.
+ On X300/X310, phase sync with UBX fully works.
- This phase offset will drift over time due to thermal and other characteristics
- Periodic calibration will be necessary for phase-coherent applications